Needle burner | inner hole diameter Φ 0.5mm ± 0.1mm, Diameter,9mm≤Φ, length ≥ 35mm, stainless steel | |
Burner angle | 0,°20°, 45° (adjust flame height) | |
Thermocouple | Ø0.5mm Type K (Ni/Cr - Ni/Al), armored sheath can withstand temperature-40°C~ 1100°C | |
Burning time | 0-999.9 s ± 0.1 s adjustable (usually selected for 30s) | |
Hold Burning time | 0-999.9 s ± 0.1 s, automatic recording, manual timeout | |
Flame Height | 12mm ± 1mm (with height measurement instruments) | |
Flame Gas | butane gas/Butane gas, min. 95% purity (can use bottled lighter gases) | |
Temperature Test Range | 0~1000°C | |
Flame Temperature Requirements | from 100 °C ± 2 °C liters to 700 °C ± 3 °C time in 23.5 seconds ± 1 seconds | |
Standard Copper Block | 4mm±0.01mm, weight.0.58g±0.01g before drilling. Cu-ETP | |
Test process | automatic control, independent convulsions | |
Chamber | ≥0.5m3 | |
Size | W1100mm×D700mm×H1300mm | |
Control | Using single chip microcomputer + touch screen control | |
Consult standard | GB/T5169.10-2006 , IEC60695-11-5:2000,UL746A | |
Power Supply | 800VA ,220V, 48-60Hz |