○测温范围及允差
●热电偶
|
|
|
型号
| 分度号
| 允许误差与偶材等级
|
I级
| II级
|
允差值
| 测温范围℃
| 允差值
| 测温范围℃
|
HR-WRNB
| K
| ±1.5℃
±0.004│t│
| -40~+375
375~1000
| ±2.5℃
±0.0075│t│
| -40~+333
333~1200
|
HR-WRMB
| N
| ±1.5℃
±0.004│t│
| -40~+375
375~1000
| ±2.5℃
±0.0075│t│
| -40~+333
333~1200
|
HR-WREB
| E
| ±1.5℃
±0.004│t│
| -40~+375
375~800
| ±1.5℃
±0.004│t│
| -40~+333
333~900
|
HR-WRFB
| J
| ±1.5℃
±0.004│t│
| -40~+375
375~750
| ±1.5℃
±0.004│t│
| -40~+333
333~750
|
HR-WRCB
| T
| ±1.5℃
±0.004│t│
| -40-~+125
125~350
| ±1℃
±0.0075│t│
| -40~+333
133~350
|
HR-WRPB
| S
| ±1℃
±[1+0.003(t-1100)]
| 0~+1100
1100~1600
| ±2.5℃
±0.0025│t│
| 0~600
600~1600 |
|
●热电阻
|
|
型号
|
分度号
|
测温范围℃
|
精度等级
|
允许偏差
|
HR-WZPB
|
Pt100
|
-200~+500
|
A级
|
±(0.15+0.002|t|)
|
B级
|
±(0.30+0.006|t|)
|
HR-WZCB
|
Cu50
Cu100
|
-50~+100
|
-
|
±(0.30+0.005|t|) |
|
注:t为感温元件实测温度绝对值
○输出信号:4~20mA,负载电阻250Ω,传输导线电阻100Ω。
○输出方法:二线制
○精度等级:
●温度变送器精度等级:0.1;0.2;0.5;
●显示器精度:模拟指示2.5级;数字显示1.0级。
○供电电源:24V.DC±10%
○防护等级:IP65
○防爆等级:
隔爆形:dIIBT4,dIICT5,dIICT6
本质安全形:iaIICT6
○绝缘电阻:
仪表输出接线端子与外壳之间的绝缘电阻应不小于50MΩ。
○热响应时间:
当温度出现阶跃变化时,仪表的电流输出信号变化至相当于该阶跃变化的50%所需的时间,通常以τ0.5表示当温度变送器的阶跃响应稳定时间不超过热电偶(阻)热响应稳定时间τ0.5的五分之一时,则用热电偶(阻)热响应时间作为仪表的热响时间;
当温度变送器的阶跃响应稳定时间不超过热电偶(阻)热响应稳定时间τ0.5的二分之一时,则用温度变送器热响应时间作为仪表的热响应时间。
○基本误差
仪表的基本误差应不超过热电偶(阻)和温度变送器基本误差的合成误差。 |