| AC WITHSTAND VOLTAGE |
|
Range |
Resolution |
Accuracy |
| Output Voltage,ACV |
0-5000@20mA |
10 |
±( 2% of setting + 5V) |
| Output Frequency |
50/60Hz±100ppm |
| Output Regulation |
±1.0% of setting+5V,from no load to full load |
| Hi Limit,current,m A |
0-20.00 |
0.01 |
| ±(2.0% of setting+2 counts) | |
| Lo Limit,current,m A |
0-9.999 |
0.001 |
| Dwell Time,second |
0,0.3-999.9 |
0.1 |
| ±(0.1% of reading + 0.05 sec) | |
| Ramp Up Time,second |
0.1-999.9 |
0.1 |
| Ramp Down Time,second |
0.0-999.9 |
0.1 |
| ARC Detection |
0-9 |
| DC WITHSTAND VOLTAGE (7140,7142 ONLY) |
| Output Voltage,DCV |
0-6000@7500u A |
10 |
±(2.0%of setting + 5 V) |
| ±(2.0%of setting + 2 counts) | |
| Hi Limit,current,u A |
0-7500 |
1 |
| Lo Limit,current,u A |
0-999.9 |
0.1 |
| Dwell Time,second |
0,0.4-999.9 |
0.1 |
±(0.1% of reading + 0.05 sec ) |
| Ramp Up Time,second |
0.1-999.9 |
0.1 |
| Ramp Down Time,second |
0,1.0-999.9 |
0.1 |
| INSULATION RESISTANCE (7132,7142 ONLY) |
| Output Voltage,DCV |
30-1000 |
10 |
±(2% of setting + 5 volts) |
| Hi Limit,Resistance,MΩ |
0-9999 |
1 |
Same as Resistance display |
| Lo Limit,Resistance,MΩ |
1-9999 |
1 |
| Ramp Up Time,second |
0.1-999.9 |
0.1 |
±(0.1% of reading + 0.05 sec ) |
| Ramp Down Time,second |
0,1.0-999.9 |
0.1 |
| Delay Time, second |
0,0.5-999.9 |
0.1 |
| MEASUREMENT |
Range |
Resolution |
Accuracy |
| Voltage, KV |
0.00- 6.00 |
0.01 |
±(2.0%of setting + 0.01KV) |
| 30-1000 |
±(2.0% of setting + 0.005KV) |
| AC Current, mA |
0.000-3.500 |
0.001 |
| ±(2.0%of setting + 2 counts) | |
| 3.00-20.00 |
0.01 |
| DC Current, uA |
0.0-350.0 |
|
| DC Current, mA |
|
0.001 |
| 3.00-7.50 |
0.01 |
|
Resistance, MΩ |
1-9999 |
0.00~9.999/0.001 10.00~99.99/0.01 100.0~999.9/0.1 1000~9999/1 |
±(2% of reading + 2 counts) @500 - 1000VDC/ 1 - 1000 MΩ ±(5% of reading + 2 counts) @500 - 1000VDC / 1000 - 9999 MΩ ±(8% of reading + 2 counts) @30 - 500V DC/ 1 - 1000 MΩ |
| GENERAL |
| Memory |
Memory10, Step3 |
| PLC Remote Control |
Test, Rest, Memory1.2.3, Interlock |
| PLC Signal Output |
Pass, Fail, Processing, Rest |
| Safety |
Built-in Smart GFI circuit |
| LCD Display |
128x64 LCD |
| Key Lock |
To prevent unauthorized alteration of the test parameters |
| Calibration |
Built-in software and external calibrated meters |
| Verification |
AC, DC, IR |
| Dimension/Wight |
215(W) x 89(H) x 370(D) mm/10Kg |
| Input Voltage |
115/230VAC ±15%,50/60HZ±5% |
| Environment |
0-40℃,RH 0-80% |