交流耐压测试 - WAC
- High = Disable
Scan Box - 1 Channel
- Voltage = 0.05 - 5kV
- High Limit = 0 - 40mA
- Low Limit = 0 - 40mA
- ARC Limit = 0 - 40mA
- Test Time = 0 - 999s
- Ramp Time = 0 - 999s
|
直流耐压测试 - WDC
- High = Disable
Scan Box - 1 Channel
- Voltage = 0.05 - 6kV
- High Limit = 0.0001 - 20mA
- Low Limit = 0 - 20mA
- Charge Low = 0 - 20mA
- ARC Limit = 0 - 20mA
- Test Time = 0 - 999s
- Ramp Time = 0 - 999s
|
泄漏电流测试 - LC
- Device =
D0 OFF
D1 UL544NP
D2 UL544P
D3 UL1563
D4 UL2601-1
D5 UL1950
- Line =
L0 NORMAL
L1 REVERSE
L2 SF-NORMAL
L3 SF-REVERSE
- High Limit = 0.0001 - 6.000mA
- Low Limit = 0 - 9.999mA
- Power =
VOLTAGE
CURRENT
VA
- Voltage High = 0 - 300V
- Voltage Low = 0 - 300V
- Test Time = 0 - 999s
|
接地电阻测试 - GR
- High = Disable
Scan Box - 1 Channel
- Current = 1-30.00A
- High Limit = 0.1 - 510mohm
- Low Limit = 0 - 510mohm
- Test Time = 0 - 999s
- Ramp Time = 0 - 999s
|
绝缘电阻测试 - IR
- High = Disable
Scan Box - 1 Channel
- Voltage = 0.05 - 1kV
- High Limit = 0.1 - 50000Mohm
- Low Limit = 0 - 50000Mohm
- Test Time = 0 - 999s
- Ramp Time = 0 - 999s
|