PERFORMANCE |
Measurement Range (RH) | 0-100% RH |
Measurement Range (T) | -30 to +70°C |
Accuracy RH @ 23°C | <±2% RH (5–95% RH) |
Accuracy T @ 23°C | ±0.2°C (-10 to +50°C) |
Stability - RH Sensor | ±1% RH/year |
Response Time - RH Sensor | <10 sec typical (90% of the step change) |
ELECTRICAL INPUT/OUTPUT |
Output Signal (RH) | 4–20mA, 0–10 V |
Output Signal (T) | 3-wire 100 Ω 1/3 DIN Pt100 |
Supply Voltage | 10–32 VDC for 4–20mA output 15–32 VDC for 0–10V output (PF211B: 24 VAC ±10%) |
Load Resistance (T) | Output 4–20mA: Rload < (Uv-9)/0.02 Output 0–10 V: R > 1KΩ |
Current Consumption | 20mA max |
OPERATING CONDITIONS |
Operating Temperature | Probe: -30 to +70°C Housing: -30 to +70°C Storage: -30 to +70°C |
Operating Humidity | Probe: 0–100% RH Housing: 0–100% RH Storage: 0–100% RH |
MECHANICAL SPECIFICATIONS |
Ingress Protection | IP54 |
Housing Material | ABS |
Electrical Connections | 5 or 6 wires output cable, 3m |
Dimensions | L=175mm, ø19mm |
Weight | 184g |