筛选
-
- 地区
- 全部
-
- 会员级别
- 全部
(50或60Hz, 测量导线位于中心的挠性循环内)
|
||||
滑动开关切换位置
|
300A AC
|
3000A AC
|
||
档位
|
3 – 300A
|
30 – 3000A
|
||
输出选择
|
300mV
|
1V
|
300mV
|
1V
|
输出讯号
|
1mV/A
|
3.33mV/A
|
0.1mV/A
|
0.333mV/A
|
误差
|
1% of full scale
|
1% of full scale
|
||
线性 (10 ~ 100%)
|
0.2% of reading
|
0.2% of reading
|
||
位置感度
|
2% of range
|
2% of range
|
||
外在误差
(从头量起200mm,
< 40A/m)
|
1% of full scale
|
1% of full scale
|
||
相位角误差
|
< ± 1°
|
< ± 1°
|
||
温度系数 (0 ~ 70°C)
|
0.02% of reading / °C
|
0.02% of reading / °C
|
||
滑动开关切换位置
|
30A AC
|
|||
档位
|
3 – 30A
|
|||
输出选择
|
300mV
|
1V
|
||
输出讯号
|
10mV/A
|
33.3mV/A
|
||
误差
|
3% of full scale
|
|||
线性 (10 ~ 100%)
|
0.2% of reading
|
|||
位置感度
|
3% of full scale
|
|||
外在误差
(从头量起200mm,
< 40A/m)
|
1% of full scale
|
|||
相位角误差
|
< ± 2°
|
|||
温度系数 (0 ~ 70°C)
|
0.02% of reading / °C
|
|||
直流零位点漂移:
|
< 20mVDC (300A AC档位)
< 100mVDC (30A AC档位)
< 20mVDC (3000A AC档位)
|
|||
噪声干扰:
|
< 2mVACRMS
|
|||
频宽 (-3dB):
|
10 ~ 10 KHz
|
|||
装置阻抗:
|
1KΩ
|
|||
一般规格:
|
||||
挠性线长度:
|
610mm (24”)
|
|||
最小弯曲直径:
|
35mm
|
|||
探测环连接头直径:
|
23mm
|
|||
连接头缆线直径:
|
14mm
|
|||
挠性缆线线长:
|
1700mm
|
|||
输出缆线线长:
|
1700mm
|
|||
仪器尺寸:
|
130mm(长) x 80mm(宽)x 43mm(高)
5.1”(长) x 3.1”(宽) x 1.7”(高)
|
|||
电池:
|
3号AA 1.5V x 2
(碱性, 2000mA 小时)
|
|||
电池寿命:
|
300小时
|
|||
工作温度:
|
-10°C ~ 85°C
|
|||
工作湿度:
|
15% ~ 85%相对湿度
|
|||
量测高度:
|
最高至 2000M
|
|||
储存温度:
|
-20°C ~ 85°C
|
|||
储存湿度:
|
15% ~ 85%相对湿度
|
|||
重量:
|
430g (含电池)
|
|||
附件:
|
说明书 x 1
1.5V电池 x 2
携带箱 x 1
|