筛选
-
- 地区
- 全部
-
- 会员级别
- 全部
Bird5019D|鸟牌5019D 4000MHZ/100W通过式功率传感器|鸟牌功率计|鸟牌功率传感器
5019D
5019D, 100mW - 100W Avg, 260W Peak Wideband Power Sensor never requires field calibration, only requires calibration once per year and is traceable to National Institute of Standards and Technology (NIST). The WPS measures True Average Power, Peak Power, and Duty Cycle directly with exceptional accuracy and uses these precise measurements to calculate a wide range of other important factors, such as VSWR, Return Loss, Reflection Coefficient, Crest Factor, Average Burst Power, and CCDF.
Included Accessories: User Manual, VPM3 - Virtual Power Meter Software and Manual, 6 ft. USB Cable.
PRODUCT SPECIFICATIONS:
Item No | 5019D |
Item Name | 100 mW - 100 W Avg, 260 W Peak Wideband Power Sensor |
Frequency Range | 25 MHz - 1.0 GHz |
Power Range |
100 mW - 100 Watts Avg. 360 Watts Peak |
Insertion VSWR | <1.05 |
Insertion Loss | <0.05 dB |
Directivity | 28 dB up to 100 MHz, 30 dB from 100 to 1000 MHz |
Average Power |
Average Forward Power Range: 100 mW - 100 Watts, 260 Watts Peak *Accuracy, Average Forward Power: ± 4% of reading, + 0.04 W Minimum Forward Power for Reflected Measurement: .3 Return Loss: 0.0 to 23 dB VSWR: 1.15 to 99.9 Rho: 0.07 to 1.0 |
Burst Average Power |
Burst Average Forward Power Range: 2.7 W - 100 Watts Avg Burst Width: 1 μs to 5 ms Repetition Rate: 200 Hz, Min Duty Cycle (D): .001 to 1.0 *Accuracy, Burst Average Power: ± 6% of reading, + 0.04 Watts |
Peak Envelope Power Range | 2.7 - 260 W |
Accuracy---Peak Envelope Power |
burst width > 200 μs: ± 7% of reading, + 0.13 W 1 μs < burst width < 200 μs: ± 10% of reading, + 0.26 W 0.5 μs < burst width < 1 μs: ± 15% of reading, + 0.26 W burst width < 0.5 μs: ± 20% of reading, + 0.26 W |
Crest Factor |
Crest Factor Measurement Range: 100 mW - 100 Watts *Accuracy, Crest Factor: Linear Sum of Peak and Average Power Accuracies |
Complementary Cumulative Distribution Function |
CCDF Measurement Range: 0.1 to 100% Threshold Measurement Range: 2.7 - 100 W Measurement Uncertainty: ± 0.2% *Level Set Accuracy: As Peak Envelope Power Accuracy + 2.0% |
Connectors | N Female (Both) |
Power Supply |
USB Port: less than one low-power USB load DC Input Connector: 7-18 VDC at less than 0.1A |
Impedance �6�8 | 50 (nominal) |
Interfaces |
DPM Interface: DB9 proprietary interface PC Interface (1): RS-232, 9600 Baud, no parity, 8 data bits, 1 stop bit, DB9 PC Interface (2): USB 2.0 Type B |
Weight | 1.2 lbs., max. |
Dimensions H x W x D |
4.8" x 4.6" x 1.3" (122 x 117 x 33 mm) |
Data Logging | Requires 5000-XT or VPM3 |
Operating Temperature | -10 to +50 °C (+14 to +122 °F) |
Storage Temperature | -40 to +80 °C (-40 to +176 °F) |
Mechanical Shock and Vibration | IAW MIL-PRF-2880F Class 3 |
CE | EMC EN 61326-1-2006 |